![Close](/skins/chameleon_hd/customer/images/close_video.png)
![Digital Insulation Resistance Tester MS5201 Mastech - 1 - Vikiwat Digital Insulation Resistance Tester MS5201 Mastech - 1](https://vikiwat.com/userfiles/productimages/19780/product_box_65590.jpg)
![Digital Insulation Tester MS5201, MASTECH - 2 - Vikiwat Digital Insulation Tester MS5201, MASTECH - 2](https://vikiwat.com/userfiles/productimages/19780/product_box_55348.jpg)
![Digital Insulation tester MS5201, 250 - 1000V, 2000 MOhm, DC and AC - 3 - Vikiwat Digital Insulation tester MS5201, 250 - 1000V, 2000 MOhm, DC and AC - 3](https://vikiwat.com/userfiles/productimages/19780/product_box_65591.jpg)
![Digital Insulation tester MS5201, 250 - 1000V, 2000MOhm, DC and AC - 4 - Vikiwat Digital Insulation tester MS5201, 250 - 1000V, 2000MOhm, DC and AC - 4](https://vikiwat.com/userfiles/productimages/19780/product_box_68154.jpg)
![Digital Insulation tester MS5201, 250 - 1000V, 2000MOhm, DC and AC - 5 - Vikiwat Digital Insulation tester MS5201, 250 - 1000V, 2000MOhm, DC and AC - 5](https://vikiwat.com/userfiles/productimages/19780/product_box_68155.jpg)
![Digital Insulation tester MS5201, 250 - 1000V, 2000MOhm, DC and AC - 6 - Vikiwat Digital Insulation tester MS5201, 250 - 1000V, 2000MOhm, DC and AC - 6](https://vikiwat.com/userfiles/productimages/19780/product_box_68156.jpg)
![MS5202 Insulation tester Mastech, DC and AC - 7 - Vikiwat MS5202 Insulation tester Mastech, DC and AC - 7](https://vikiwat.com/userfiles/productimages/19780/product_box_68157.jpg)
![Mastech MS5201 Digital Insulation Tester AC/DC Voltage - 8 - Vikiwat Mastech MS5201 Digital Insulation Tester AC/DC Voltage - 8](https://vikiwat.com/userfiles/productimages/19780/product_box_68158.jpg)
1. Never exceed the limit values indicated on the scale for each measurement range.
2. Do not touch the non-insulated probe parts when measuring.
3. Never use the meter to measure voltages higher than 700VAC and 1000VDC.
4. When the value of the measured parameter is unknown, the instrument is set to the maximum range.
5. Before selecting another measurement parameter, remove the probes from the previous measurement.
6. When measuring impulse power supply, be aware that high impulse values can damage the unit.
7. The safe touch voltage is up to 60 VDC, 30 VAC rms.
8. Never measure impedance in a circuit with a supply voltage included. In the resistance measurement mode, do not measure the voltage. In the current measurement mode, do not measure the voltage.